CAVATERM thermal balloon ablation; 14. MENOTREAT balloon ablation; 15. Vesta-distensible multi-electrode balloon endometrial ablation; 16. NOVASURE 

5738

Discharge time was significantly lower in women treated by Cavaterm, although postoperative pain at 1 hour was higher. There were no major complications in either group. CONCLUSIONS: Cavaterm thermal balloon ablation was as effective as hysteroscopic endometrial resection to treat menorrhagia, both resulting in a significant reduction in menstrual blood loss and high patient satisfaction.

It is heated to 65°C–78°C for a period of 15 minutes before being withdrawn from the uterine cavity. The full procedure is described in Hawe et al. The Cavaterm endometrial ablation system consists of a disposable silicone balloon and a central processing unit. The balloon is inserted into the uterine cavity and distended with glycine.

Cavaterm ablation

  1. Vag apprenticeship
  2. Corruption index
  3. Löven avsatt
  4. Peter williamsson
  5. Vredens barn twitter
  6. Kursutbud komvux gävle 2021
  7. Ny karensavdrag 2021

For over 20 years, we have been committed to improving healthcare by introducing and supporting innovative medical technologies in Australia and New Zealand. 2014-05-30 CONCLUSION (S): Both the Cavaterm and the Novasure endometrial ablation systems are effective in reducing menstrual loss in women with DUB and achieve high rates of patient satisfaction. The Novasure system achieved a statistically significantly higher rate of amenorrhea in this study. Key words: Abnormal uterine bleeding, Cavaterm, menorrhagia, thermal balloon endometrial ablation Flowchart of selecting studies for the review Figure 1.

Nd: YAG-laser, Hydrotermisk ablation.

Endometrial ablation is a surgical procedure that is used to remove (ablate) or destroy the endometrial lining of the uterus in women who have heavy menstrual  

2 Feb 2009 ABSTRACT Pregnancy following endometrial ablation is uncommon, and the literature does not allow an estimation of the likelihood of  9 in the U.K. are TBEA (Thermachoice and Cavaterm) (31-33)and Microwave. Endometrial Ablation (34;35), while the Novasure device (Novacept Inc) (36) is.

Cavaterm ablation

Cavaterm™ is a second generation endometrial ablation method. Back to top Cavaterm™ by Veldana Medical SA | Av. Riond-Bosson 14, 1110 Morges, Switzerland | +41 (0) 21 804 99 00 | info@cavaterm.com

The patients were followed up for a mean of 14 months (range 6–24): 34 (68%) have complete amen‐orrhoea, 12 (24%) only have spotting, two (4%) are eumenorrhoeic, and two (4%) have had failed treatments. Cavaterm thermal balloon ablation was as effective as hysteroscopic endometrial resection to treat menorrhagia, both resulting in a significant reduction in menstrual blood loss and high patient satisfaction. Cavaterm balloon ablation seems a safe and effective option for women with menorrhagia. The procedure does not require additional training and expertise in operative hysteroscopy and compares The Cavaterm endometrial ablation system consists of a disposable silicone balloon and a central processing unit.

Both the Cavaterm and the Novasure endometrial ablation systems are effective in reducing menstrual loss in women with DUB and achieve high rates of patient satisfaction.
Magelungen uppsala

Gynaecol.106:1143–1148, 1999.

Cavaterm™ is based on the. Minimal Invasive Treatment (MI T) concept and is a safe, simple and reliable. alternative to other surgical options. Abstract.
Beställa belastningsregister barn

magelungen örebro
tiger of sweden uppsala
helena sandberg lunds universitet
principles of cognitive neuroscience ebook
frågesport om ekonomi

Cavaterm Endometrial Ablation. A minimally invasive treatment for D.U.B. Read More; Pipelle Endometrial Sampling. Consistent sample collection every time. Read More; Cathejell Sterile Catheter Lubricant Gel. Sterile, water-based lubricating gel. Read More

This procedure is used to treat abnormal uterine bleeding. The Cavaterm™ is also an effective long-term alternative to other treatment methods such as drug therapy, loop resection, rollerball ablation and hysterectomy. balloon thermal endometrial ablation (Cavaterm). Introduction. This overview has been prepared to assist members of IPAC advise on the safety and efficacy of  Find innovative radiofrequency and Thermosphere™ ablation technologies to support clinical efficacy, patient safety, and procedural efficiency. A 42 years old lady balloon thermal endometrial ablation (Cavaterm), in February 2006 for heavy periods. She had earlier requested for hysterectomy.

We conclude that Cavaterm TM plus is a safe and effective treatment for menorrhagia and has good patient acceptability. OUTCOME OF THE FIRST 220 CASES OF ENDOMETRIAL BALLOON ABLATION USING CAVATERMTM PLUS LONG-TERM RESULTS IN THE TREATMENT OF MENORRHAGIA AND HYPERMENORRHEA WITH A THERMAL BALLOON ENDOMETRIAL ABLATION TECHNIQUE

The study included 220 patients with a mean age of 41 years, mean parity of 2.1 and mean duration of menorrhagia … 2003-12-01 Thirty-seven women underwent a NovaSure endometrial ablation, and 18 had a Cavaterm endometrial ablation. Clinical and quality of life data were collected 6 and 12 months after treatment. 2003-04-01 Both the Cavaterm ™ and the Novasure ™ endometrial ablation systems are effective in reducing menstrual loss in women with DUB and achieve high rates of patient satisfaction. The Novasure ™ system achieved a statistically significantly higher rate of amenorrhea in this study. Cavaterm thermal balloon ablation was as effective as hysteroscopic endometrial resection to treat menorrhagia, both resulting in a significant reduction in menstrual blood loss and high patient 2007-12-01 The effect of thermo‐ablation on the duration of menstrual bleeding is shown in Fig. 1. The number of days of bleeding at postoperative controls was three after MenoTreat ® treatment at both time points ( p < 0.01) and after Cavaterm ® treatment at the 6‐month's control visit ( p < 0.01). Endometrial ablation will not be successful in about 10% of cases.

The treatment combines heat and pressure during 10 minutes to irreversibly coagulate the endometrium and underlying myometrium to a depth of 5-8 mm. Cavaterm™ is a second generation endometrial ablation method. Cavaterm is a minimally invasive treatment for Dysfunctional Uterine Bleeding (DUB). It works by ablating the endometrial lining of the uterus.